Siemens SIMATIC STEP 7 v5.6 Keygen Serial

ScreenShots:

Software Description:

Siemens SIMATIC STEP 7 software is theprofessional tool for the SIMATIC S7, SIMATIC C7 and SIMATIC WinACautomation systems. It enables the user to use the performancecapability of these systems easily and conveniently.

SIMATIC STEP 7 contains convenient functions for all phases of anautomation project:
– Configuring and parameterizing the hardware
– Specifying the communication
– Programming
– Test, start-up and service
– Documentation, archiving
– Operating/diagnostics functions

SIMATIC STEP 7 program tools:
1. SIMATIC-Manager:
The SIMATIC Manager manages all data belonging to an automationproject, regardless of the target system (SIMATIC S7, SIMATIC C7 orSIMATIC WinAC) on which they are implemented.
It provides a common entry point for all SIMATIC S7, C7 or WinACtools. The SIMATIC software tools that are necessary for processingthe selected data are automatically started by SIMATIC Manager.

2. Symbol-Editor:
With the tool Symbol Editor all global variables (in contrast tothe local formal parameters that are declared when the blocks areprogrammed) are managed. The following functions are available:
– Definition of symbolic designations and comments for the processsignals (inputs/outputs), flags and blocks
– Sorting functions
– Data exchange with other Windows programs

The symbol charts that are generated when this tool is used areavailable to all software products. Changes to a symbol parameterare therefore automatically recognized by all tools.

3. Hardware configuration:
The tool Hardware Configuration is used for configuring andparameterizing the hardware used for an automation project. Thefollowing functions are available:

– Configuration of the automation system  Racks are selectedfrom an electronic catalog and the selected modules are assigned tothe required slots in the racks.

– The configuration of the distributed I/Os is done in the same wayas the configuration of the non-distributed I/Os; channel-granularI/O modules are also supported.

– CPU parameter assignment:
Properties such as restart characteristics and cycle-timemonitoring can be set menu-driven. multicomputing is supported. Theentered data are filed in system data blocks in the CPU.

– Module parameter assignment:
The user can specify all the adjustable parameters of the modulesin input screen forms. Adjustments via DIP switches becomeunnecessary. Parameterization of hardware modules occursautomatically during the CPU’s acceleration. Thus, a change of amodule can be made without another parameterization.

– Function module (FM) and communications processor (CP) parameterassignment:
This parameterization also occurs within the hardware configurationin the same way as the parameterization of the other modules. Forthis parameterization hardware-module-specific screen forms andrules are provided for each FM and CP (is included in the FM/CPfunctions package). The system prevents faulty inputs by offeringonly allowed entry options on the parameter assignment screenforms.

4. Communication configuration:
– Configuring and display of communication links
– Time-driven cyclic data transmission via MPI:
    – Selection of communication partners
    – Entering of data source and data destinationin a table.Generation of all system data
      blocks (SDBs) to be loaded and theircomplete transmission to all CPUs take place
      automatically
    – Parameterization of the selected communicationblocks in the customary programming
      language (e.g., LAD). 
Event-driven data transmission
– Definition of the communication links.
– Selection of the communication function blocks (CFBs) from theintegrated block library.
– Parameterization of the selected communication blocks in thecustomary programming
  language (e.g., LAD).

5. System diagnostics:
System diagnostics offer the user an overview of the status of theautomation system. The display can be in two different forms:
– Display of text messages, which can be output directly andquickly.
– Pixel-graphics display within the Hardware Config display,offering the following options:
 – Display of general module information (e.g., order number,version, designation) and
  module status (e.g., faulty)
 – Display of module faults (e.g., channel faults) of thecentral I/O and DP slaves
 – Display of alarms from the diagnostics buffer

For CPUs, additional information is displayed
– Causes of malfunction during user program execution.
– Display of cycle duration (longest, shortest and last cycle).
– Display of the reserved and free memory.
– Capabilities and usage of MPI communication.
– Display of the performance data (number of possibleinputs/outputs, flags, counters, timers and blocks)

Installer Size: 2417 + 53 + 60 + 230 MB

Download Links : Siemens SIMATIC STEP 7 v5.6 + S7-GRAPH v5.6 + S7-SCL v5.6 + S7-PLCSIM v5.4 SP8 x64 for Windows 10 + Crack



Copy the download link and paste to your browser